Publications

Filter
Topic
Publication State
Showing 1 - 10 of 141 Publications
Water Retention of Concrete – Filtration
This test method is used to measure the ability of a concrete with a maximum coarse aggregate size of 20 mm or less to retain its water under pressure. This test determines the amount of water de-filtered when concrete is subjected to a certain…
Supply of Special Class Concrete
Austroads Technical Specification ATS 5315 sets out the requirements for the supply of Special Class Concrete used in: bridges with a design life of 100 years
Repair of Concrete Cracks
Austroads Technical Specification ATS 5341 sets out the requirements for the repair of cracks in concrete, including supply and quality of materials, surface preparation, application, relevant testing and acceptance criteria. The technical…
Coring of Hardened Concrete
Austroads Technical Specification ATS 5317 sets out the requirements for the coring of hardened concrete for the purpose of assessing the in-situ concrete properties, including compressive strength, volume of permeable voids and density. It does not…
Code of Practice for the Management of Alkali Aggregate Reactivity Template
The Code of Practice for the Management of Alkali Aggregate Reactivity template has been developed for the use of Austroads member agencies. The document outlines the management strategies, testing and approval process required to regulate alkali…
High Workability Concrete - Verification of Properties and Performance Criteria
Transport for New South Wales (TfNSW) QA Specification B80 'Concrete work for Bridge' (TfNSW B80)10 has seen continual improvement over the years. These improvements adopted recent industry trends and new technologies including self-compacting…
Effects of increasing Limestone content of cement on concrete performance
In attempts to reduce the CO2 footprint of the construction industry, technologies have been developed in the past for the replacement of Portland cement by other materials, such as supplementary cementitious materials (SCMs), which have had the…
Bridge Strengthening Design and Construction - Dynon Road Bridge over Moonee Ponds Creek, West Melbourne
The Dynon Road Bridge over Moonee Ponds Creek is a 12-span, 61 metre long cast in-situ concrete flat-slab bridge constructed in 1941. This art-deco style bridge is heavily trafficked and an important link between Melbourneís western suburbs and the…
Concrete Technology and Durability in TMR - Past, Present and Future
This paper will give a brief history of our concrete technology and concrete durability journey within TMR QLD over the last 20 years together with our present position and issues, and where we see some of our future challenges and development.…
'Smart' bridge components (expansion joints, bearings, seismic devices) for intelligent infrastructure
The potential benefits of using structural health monitoring systems in measuring and recording bridge data have been established in many applications around the world, but the efficiency and effectiveness of such systems depends on how they are…